Find Transfer Switches By: | Cummins Onan OTPC PowerCommand Service Entrance Series: 40 - 600 AmpsOTPC|Service Entrance|3 & 4 Pole|40 - 600 AMPSPart #:cummins-otpc-service-entrance-transfer-switch Cummins Power Generation’s Service Entrance Transfer
Switches are designed for operation and switching of
electrical loads between primary power and standby
generator sets. They are suitable for use in emergency,
legally required and optional standby applications. Need More info?
Call our experienced generator specialists : 1 800 922 5632. If you would like a Continental Generators representative to contact you please submit our customer inquiry form and we will assist you as soon as possible
- PowerCommand® control - A standard, fully featured
microprocessor-based control.
- Software-enabled
features, settings, and adjustments are available for ease
of setup and accuracy.
-
Overcurrent disconnect device - UL Listed 489,
Square D breaker.
-
Robust control system design
- Optically isolated
logic inputs and high isolation transformers for AC power
inputs provide high-voltage surge protection
-
Communications capability
- The transfer switch is
capable of communicating with other transfer switches
-
Accessories with a SCADA network or with Cummins
Power Generation generators utilizing LonWorks®
protocol.
-
Main contacts
- - Heavy-duty silver alloy contacts with
separate arcing surfaces and multi-leaf arc chutes are
rated for total system transfer including overload
interruption.
-
Easy service/access
- Plug connections, doormounted
controls, ample access space for both all top
and all bottom power connections, and compatible
terminal markings.
- The control is field programmable.
-
Product lines, accessories and services
- Cummins Power Generation offers a wide range of
accessories and services to suit your requirements.
- Warranty and service - Backed by a comprehensive warranty and worldwide distributor network.
Specifications
- Voltage rating Transfer switches rated from 40 A through 600 A are rated up to 480 VAC, 50 or 60 Hz.
-
Arc interruption Multiple leaf arc chutes cool and quench the arcs.
- Covers prevent interphase flashover and are
transparent for visual inspection.
-
Neutral bar A full current-rated neutral bar with lugs is standard on enclosed 3-pole transfer switches.
-
Auxiliary contacts Two contacts (one for each source) are provided for customer use.
- Wired to terminal block for easy
access.
- Rated at 10A continuous and 250 VAC maximum.
-
Operating and storage
temperature -13 °F (-25 °C) to 140 °F (60 °C) (breaker operating temperature)
-
Humidity Up to 95% relative, non-condensing
-
Altitude Up to 10,000 ft (3,000 m) without derating
Surge withstand ratings Surge-tested for location category B3, per IEEE C 62.41.
- Testing per IEEE 62.45. Control tested to
-
European Surge Test EN 61000-4-5.
- Total transfer time (sourceto-
source)
- Will not exceed 6 cycles at 60 Hz with normal voltage applied to the actuator and without programmed
transition installed.
- Manual operation handles
- Transfer switches rated through 1000 A are equipped with permanently attached operating handles and
quick-break, quick-make contact mechanisms suitable for manual operation.
- Transfer switches over 1000
A are equipped with manual operators for service use only under de-energized conditions.