Asco 300 Series 260 Amp Automatic Transfer Switch - 2 Pole

300 Series|Automatic|2 Pole|260 AMP

Part #:Asco-260AMP-2Pole

Call Us
for Price
1-800-922-5632

  View Spec Sheet

Easy-to-read flush-mounted control and display panel provides LED indicators for switch position and source availability. It also includes test and time-delay bypass switches as standard features. Standard engine exerciser for weekly automatic testing of engine generator set with or without load. Adjustable time-delay feature prevents switch from being activated due to momentary utility power outages and generator dips.

Need More info?

Call our experienced generator specialists : 1 800 922 5632. If you would like a Continental Generators representative to contact you please submit our customer inquiry form and we will assist you as soon as possible

  • The SERIES 300 is listed to UL 1008 standard for Transfer Switch Equipment and CSA standard C22.2 for automatic transfer switches.
  • Meets NFPA 110 for Emergency and Standby Power Systems and the National Electrical Code (NEC) Articles 700, 701 and 702.
  • 30 through 3000 amps in a compact design.
  • Available to 600 VAC, single or three phase.
  • True double-throw operation: The single solenoid design is inherently inter locked and prevents contacts from stopping between sources or from being in contact with both sources at the same time.




  • The ATS shall be furnished in a NEMA type 1 enclosure unless otherwise shown on the plans.
  • Provide strip heater with thermostat for Type 3R enclosure requirements.
  • Controller shall be flush-mounted display with LED indicators for switch position and source acceptability.
  • It shall also include test and time delay bypass switches.
  • Voltage and Frequency Sensing
  • The voltage of each phase of the normal source shall be monitored
  • Pickup adjustable to 95% of nominal and dropout adjustable from 70% to 90% of pickup setting.
  • Single-phase voltage and frequency sensing of the emergency source shall be provided.
  • An adjustable time delay provided to override momentary normal source outages
  • Delays all transfer and engine starting signals.
  • An adjustable time delay provided on transfer to emergency
  • Adjustable from 0 to 5 minutes for controlled timing of transfer of loads to emergency.
  • A generator stabilization time delay shall be provided after transfer to emergency.
  • An adjustable time delay shall be provided on retransfer to normal, adjustable to 30 minutes.
  • Time delay shall be automatically bypassed if emergency source fails and normal source is acceptable.
  • A 5-minute cooldown time delay shall be provided on shutdown of engine generator.
  • All adjustable time delays shall be field adjustable without the use of special tools.
Telecom, Agriculture,Municipal,Commercial /Retail, Light Industrial

Featured Product

Robin Subaru RGD5000H Portable Generator - Robin Subaru RGD5000H Portable Generator - great for emergency generator use.

click here for more info