Asco 185 Series 200 Amp Transfer Switch

185A2200F4C|Type 1 Indoor|2 Pole|200 AMP

Part #:185A2200F4C

Call Us
for Price
1-800-922-5632

  View Spec Sheet

True double-throw contacts with inherent mechanical interlocking to prevent connection of generator and utility sources

Need More info?

Call our experienced generator specialists : 1 800 922 5632. If you would like a Continental Generators representative to contact you please submit our customer inquiry form and we will assist you as soon as possible

  • User-friendly control interface with easy to understand symbols and visual indicators to inform operator of transfer switch and power source status.
  • Listed to UL 1008 for optional standby systems, handling total system load including motors and all other electrical loads. cUL Listed for Canadian installations.
  • Meets Article 702, NFPA-70 National Electric Code (NEC) requirements.
  • Nominal service voltage 240V 50/60Hz, single phase, 3 wire AC systems.
  • Available in 100 through 400A ratings.
  • True double-throw contacts with inherent mechanical interlocking to prevent connection of generator and utility sources.
  • Terminals for convenient connection of neutral and ground conductors.
  • Available in NEMA Type 1 Indoor (steel) and Type 3R Outdoor (aluminum) enclosures, with hinged door designs.
  • Textured RAL 7035 light beige color aesthetically suitable for residential applications.
  • Available in load-break manually operated version, up to 230A.
    Series 185 Control Panel
  • Push Buttons
  • On the front control display are three push buttons that control the operation of the generator and the ATS.
  • Before using the transfer test button, be sure that conditions are safe for running the generator and for load transfer.
  • Transfer Test:
  • Use this button to test the system. This operation starts the generator and transfers the load.
  • Be sure that conditions are safe to do this operation.
  • Bypass Time Delay:
  • Use this button to cancel the active time delay or exercise period (stops the generator after cooldown).
  • Set Engine Exerciser:
  • Use this button to set the automatic generator exerciser
  • Indicator Lights
  • On the front control display are five lights that indicate the status of the sources and the ATS.
  • Utility Acceptable:
  • This light indicates that the utility voltage is acceptable for connection to the load.
  • Generator Acceptable:
  • This light indicates that the generator voltage is acceptable for connection to the load.
  • Load on Utility:
  • This light indicates that the generator voltage is acceptable for connection to the load.
  • Load on Generator:
  • This light indicates that the generator voltage is acceptable for connection to the load.
  • Automatic Generator Exerciser:
  • When the utility is acceptable and the load is on the utility, this light flashes the number of days until the next exercise period.
  • When it is off, no exerciser period is set.
  • The light is also off when the generator is running.
  • User-adjustable Settings
  • Time Delays
  • Adjustable 1 or 3 second time delay for overriding momentary
  • utility source disruptions
  • Adjustable 0 or 4 second time delay while on standby source to ignore momentary generator voltage dips
  • 5 minute time delay before load retransfer back to utility source, to ensure stability of utility power
  • Adjustable 2 or 5 minute unloaded running time delay allows generator to cool down prior to shutdown 10 second time delay before load transfer to emergency source, to allow generator warm-up and stabilization
Type 1 Indoor